General Parameters

The general debugging and diagnostic parameters are described in the table below.

General Debugging and Diagnostic Parameters

Parameter

Description

'Delay After Reset [sec]'

configure voip > sip-definition advanced-settings > delay-after-reset

[GWAppDelayTime]

Defines the time interval (in seconds) that the device's operation is delayed after a restart.

The valid range is 0 to 45. The default is 7 seconds.

Note: This feature helps overcome connection problems caused by some LAN routers or IP configuration parameters' modifications by a DHCP server.

configure system > hw > dual-powersupply-supported

[DualPowerSupplySupported]

Enables the device to send an SNMP alarm (acPowerSupplyAlarm) for one or both Power Supply modules if a module is removed from the chassis or not operating correctly (failure).

[1] = (Default) Disable. The alarm is applicable only to the main Power Supply module (#1). The device sends the alarm if this module is removed from the chassis or fails. The alarm is not sent for the secondary Power Supply module (#2) even if it is removed or fails.
[2] = Enable. The alarm is applicable to both Power Supply modules. If any of the modules are removed or fail, the device sends the alarm, indicating the affected module.

Note:

For the parameter to take effect, a device restart is required.
If configured to [2], make sure that the device is installed with two Power Supply modules. If only one module is installed, the device will send an alarm indicating a removed module.
If you want to use only one Power Supply module for the device, make sure that the parameter is configured to [1]; otherwise, an alarm will be raised indicating a removed module.

[EnableAutoRAITransmitBER]

Enables the device to send a remote alarm indication (RAI) when the bit error rate (BER) is greater than 0.001.

[0] = Disable (default)
[1] = Enable